U/UTP Category 5e LSZH Cable Dca Class
U/UTP Category 5e LSZH Cable Dca Class
- Complies to latest Cat 5e standard version
- Guaranteed performance up to 100MHz
- RoHS EC Directive 2002/95/EC compliant
- LSZH sheath
Description
Description
Standards
- 
                                            ProductANSI/TIA-568-C.2; EN 50173-1; IEC 61156-5
- 
                                            InternationalISO/IEC 11801
Application
Nexans U/UTP Category 5e cables are the standard 100MHz offering from Nexans. Manufactured in accordance with ISO IEC 61156-5 and TIA 568B requirements, this cable is the best choice to support all Class D applications like Ethernet, Fast Ethernet, Gigabit Ethernet, … Cat 5e U/UTP cables are suitable for basic voice and data installations up to 100 MHz.
Performance
Nexans Category 5e cables are compliant with the requirements of EN 50288 and ISO IEC 61156-5 standards. Used with Cat 5e connectivity, these cables are compliant with Class D link requirements as described in EN 50173 Edition 2 and ISO 11801 Edition 2 standards (2002).
Features
- 4 twisted pairs
- Compact design for minimum volume in ducts or trails
- LSZH sheath
- Design for easy and quick installation
- Solid 24 AWG cable
- RoHS EC Directive 2002/95/EC compliant
Characteristics
Characteristics
Construction characteristics
Construction characteristics
                                                            Type of cable
                                                        
                                                        
                                                            UTP 
                                                        
                                                    
                                                            Halogen free
                                                        
                                                        
                                                            IEC 60754-1 
                                                        
                                                    
                                                            Outer sheath
                                                        
                                                        
                                                            LSZH 
                                                        
                                                    Dimensional characteristics
Dimensional characteristics
                                                            Approximate weight
                                                        
                                                        
                                                            30 kg/km
                                                        
                                                    
                                                            Conductor cross-section (AWG/KCMIL)
                                                        
                                                        
                                                            24 
                                                        
                                                    
                                                            Nominal outer diameter
                                                        
                                                        
                                                            4,9 mm
                                                        
                                                    Electrical characteristics
Electrical characteristics
                                                            Capacitance unbalance pair to ground
                                                        
                                                        
                                                            1600 pF/km
                                                        
                                                    
                                                            Characteristic impedance
                                                        
                                                        
                                                            100 Ohm
                                                        
                                                    
                                                            Dielectric withstand voltage, 50Hz 1mn
                                                        
                                                        
                                                            1 kV
                                                        
                                                    
                                                            Insulation resistance at 20°C
                                                        
                                                        
                                                            5000 MOhm.km
                                                        
                                                    
                                                            Max. DC resistance of the conductor at 20°C
                                                        
                                                        
                                                            93,8 Ohm/km
                                                        
                                                    
                                                            Mutual capacitance
                                                        
                                                        
                                                            5,6 nF/km
                                                        
                                                    Transmission characteristics
Transmission characteristics
                                                            Nominal Velocity of Propagation (NVP)
                                                        
                                                        
                                                            68 %
                                                        
                                                    
                                                            Propagation delay, max. 100 MHz
                                                        
                                                        
                                                            536 ns/100m
                                                        
                                                    
                                                            Skew
                                                        
                                                        
                                                            45 ns/100m
                                                        
                                                    Usage characteristics
Usage characteristics
                                                            Ambient installation temperature, range
                                                        
                                                        
                                                            0 ... 50 °C
                                                        
                                                    
                                                            Flame retardant
                                                        
                                                        
                                                            IEC 60332-1 
                                                        
                                                    
                                                            Gases corrosivity
                                                        
                                                        
                                                            IEC 60754-2 
                                                        
                                                    
                                                            Minimum dynamic operating bending radius
                                                        
                                                        
                                                            20,0 mm
                                                        
                                                    
                                                            Minimum static operating bending radius
                                                        
                                                        
                                                            40 mm
                                                        
                                                    
                                                            Operating temperature, range
                                                        
                                                        
                                                            -20 ... 60 °C
                                                        
                                                    
                                                            Smoke density
                                                        
                                                        
                                                            IEC 61034 
                                                        
                                                    Our websites
Select your country to find our products and solutions
- 
                        Africa
                        
                        
                        - Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
 
- Americas
- Asia
- Europe
- Oceania